Analyseur de mesure fixe
SIGNAL S4 QUASAR : Analyseur de NOx
Caractéristiques
Type Temperature Ranges are user defined. Examples…
Heated vacuum pump,
Single detector
190 °C 0–1 ppm, 0–5 ppm, 0–10 ppm,
0–50 ppm, 0–100 ppm
0–500 ppm, 0–1000 ppm
Heated vacuum pump, dual detector
190 °C 0–1 ppm, 0–5 ppm, 0–10 ppm,
0–50 ppm, 0–100 ppm
0–500 ppm, 0–1000 ppm
Without pump,
Single detector
50 °C
Non-condensing at ambient temperature
0–10 ppm,
0–50 ppm, 0–100 ppm
0–500 ppm, 0–1000 ppm
Technical specifications:
Measurement technique: Chemiluminescence detector (CLD)
Units of measurement: PPM or mg/m³. User-selectable
Measurement ranges: • Range A: 0–1000 ppm:
User-configurable to 0–1 ppm, 0–5 ppm, 0–10
ppm, 0–50 ppm, 0–100 ppm, 0–500 ppm, 0–1000 ppm.
Resolution: 0.01 ppm
• Range B: 0–10,000 ppm:
User-configurable, e.g. 0–10 ppm, 0–50
ppm, 0–100 ppm, 0–500 ppm, 0–1,000 ppm, 0–
5000 ppm. 0–10,000 ppm. Resolution: 0.1 ppm
• Range C: 0–100,000 ppm:
User-configurable, with a resolution of 1 ppm.
Response time: T90 <2.0 s
Repeatability: <1% FSD
Quenching effect: CO₂ and H₂O quenching. 2% of reading per 15%
CO₂ and 2% of reading per 2% H₂O
Linearity: ± 0.5% FSD or 2% of the point EN14181 - dc rel: <2%
R²: >0.99
Zero drift: <0.5% FSD/24 hours
Temperature effect on zero: <0.15% per °C
Temperature effect on span: <0.3% per °C
Zero noise: <0.1 ppm
Span noise: < ±0.1% FSD for the vacuum version
< ±0.3% FSD for the non-vacuum version
Detection limit: 0.05 mg/m³
Bypass flow sensitivity: Less than 0.5% from 1 to 3 L/min
Sampling filter: Removable 0.4-micron PTFE
Display: Vacuum or detachable screen
Sample conditions: Maximum pressure of 190 °C
Pressure: -0.3 bar to +0.5 bar
Operating conditions: Ambient temperature 5–40°C
Air supply: Air flow rate for ozone (O3): 140 ml/min
Pressure: 0–1 bar max, dew point 12°C
Stable O2 concentration: >20%
Converter efficiency: NOx > 95%
NH3 > 85%
Outputs: 0–10 V DC
RS232
Ethernet
TCP/IP
4–20 mA option
Available power supplies: 220–240 V AC
110–120 V AC
24 V DC
600 W max.
Remote control: AK protocol via RS232 port,
Ethernet
Supplied with the S4i remote operating system.
Dimensions and weight: 19 in x 133.5 mm (H) x 530 mm (D)
Approx. 30 kg
Points forts
Flexible:
Very high suction capacity with a vacuum pump or atmospheric pressure version
‘Hot’ and ‘cold’ versions
Easy to use:
Fully automatic operation
Wireless tablet.
Software suite accessible via Ethernet or RS232
Accurate:
Dual detector for continuous readings of NO₂, NO and NOx
Measurements in PPM (parts per million) in standard trace mode
Wide measurement range, percentage display available
A wide range of user-defined alarms are available for conditions such as:
1. Concentration limit (user-defined)
2. Sample flow rate (out-of-range limits)
3. Pump failure
4. Heater failure
5. Voltage out of range
6. Thermocouple failure
7. EHT out of range
8. Configuration error
9. Options set incorrectly
10. Incorrect calculations (no calibration settings)
GASES:
NOx / Nitric oxide / Nitrogen dioxide / Ammonia
Applications:
CEMS / Research / Compliance / Gas purity / Automotive / Air quality / Process / Combustion.
Fourni avec
A chemiluminescence detector (CLD) for measuring NOx in engine emissions, combustion studies, treatment plants, continuous emissions monitoring systems (CEMS) and the production of medical gases.