Hygiène
JCT JH3FG & JH3FGR : Lignes échantillon chauffées, tresse de protection PA
Caractéristiques
Temperature-controlled heating up to a maximum of 200°C.
- Outer jacket made of flexible polyamide protective braiding.
- Thermal insulation made of silicone foam.
- Ready to use.
- Highly flexible.
- Interchangeable inner core for JH3FGR.
- Second core for, for example, optional calibration gas.
- Optional integrated temperature controller.
- Inner core reinforced with stainless steel braiding.
Model JH3FG / JH3FGR
Description: Regulated heated sampling line
Outer protective sheath: Polyamide braiding, black
Inner core: Fixed, interchangeable
Application: Mobile and stationary installation, indoors and outdoors
Operating data
Operating temperature: max. 200°C.
Operating pressure: max. 10 bar.
Ambient temperature*: -30°C to +60°C
Build
Inner core material: PTFE, optionally PFA
Heating element: DIN-compliant design, moisture-proof with protective braiding
Thermal insulation: Closed-cell, moisture-proof, thermally stabilized silicone tubing
End configurations: Hard caps or silicone caps
Maximum sampling line length*: 50 m
Outer diameter of the sampling line: DN 4/6 mm / 42 mm ± 3 mm, DN 6/8 mm / 42 mm ± 3 mm, DN 4/6 mm / 42 mm ± 3 mm, DN 6/8 mm / 48 mm ± 3 mm
Minimum bend radius JH3FG / JH3FGR: DN 4/6 mm: 50 mm / 100 mm, DN 6/8 mm: 75 mm / 120 mm
Dimensions of silicone caps [mm]: DN 4/6: L = 88, Ø 50 (H), Ø 70 (C), DN 6/8: L = 88, Ø 50 (H), Ø 70 (C)
Dimensions of PA plugs [mm]: DN 4/6: L = 111, Ø 50 (F), Ø 75 (A), DN 6/8: L = 111, Ø 50 (F), Ø 75 (A), DN 4/6: L = 111, Ø 50 (F), Ø 75 (A), DN 6/8: L = 120, Ø 54 (F), Ø 79 (A)
Protection class: IP 44 (EN60529)
Electrical
Power supply: 230 VAC 50/60 Hz or 115 VAC 50/60 Hz
Power consumption: 100 W/m
Connection cable: 3 m
Connection plug: 7-pin plug for connecting HT-43 and HT-55 temperature controllers
HANQ8 plug for connecting the HT-41 temperature controller
Integrated HT 54 temperature controller option
Installation location: Directly on the end of the hard cap
Power supply: 230 VAC 50 to 60 Hz / 115 V 60 Hz
Switching capacity: max. 1000 W / 5 A (max. 10 m at 230 V and 5 m at 115 V)
Temperature range: 0°C to 254°C, adjustable in 2°C increments using a DIP switch
Temperature sensor: PT 100
Housing material: Glass-reinforced PA
Protection class: IP 42
Optional sealing: IP 65 (fixed temperature setting)
Points forts
- No condensation, no freezing.
- Small bend radius possible.
- Excellent thermal insulation.
- Optimal heat dissipation.
- Custom configurations.
- Easy replacement of the inner core (JH3FGR).
- Long service life, even in portable applications.
- Kink protection.
Fourni avec
- Exhaust gas analysis.
- Emissions and process monitoring.
- Transport of the gas sample from the sampling point to the analysis system.
- To remain safely above the acid dew point.
- Protection against measurement tampering and freezing.
- Indoor and outdoor use.