Hygiène

JCT JH3F & JH3FR : Lignes d'échantillonnage chauffées avec tuyau ondulé

Veuillez entrer votre adresse email pour télécharger la fiche

×

Caractéristiques

Heating controlled up to a maximum of 200°C.

External protection: corrugated polyamide casing.

Thermal insulation provided by a heat-sensitive non-woven fabric.

Ready for use.

Interchangeable inner core for the JH3FR.

Second core for optional calibration gas for example.

Inner core reinforced with stainless steel braiding.


Technical specifications:

Model JH3F / JH3FR

Description: Regulated heated sampling line

External protective sheath: Corrugated polyamide sheath, black

Inner core: Fixed, interchangeable

Field of application: Mobile and fixed installations, indoors and outdoors

Operating data

Operating temperature: max. 200°C.

Operating pressure: max. 10 bar.

Ambient temperature*: From -30°C to +60°C

Construction Material of inner core: PTFE, optionally PFA

Heating element: DIN-compliant design, moisture-proof with protective braiding

Thermal insulation: Thermo-polar

Extremities configurations: PA hard caps, silicone caps, PG36 or PG42.

Maximum sampling line length*: 50 m

Outer diameter of sampling line: DN 4/6 mm / 42 mm, DN 6/8 mm / 42 mm

Minimum bend radius

JH3F / JH3FR:

DN 4/6 mm: 100 mm / 150 mm

DN 6/8 mm: 150 mm / 200 mm

Dimensions of silicone caps:

DN 4/6 : L = 88, Ø 50 (H), Ø 70 (C)
DN 6/8 : L = 88, Ø 50 (H), Ø 70 (C)
Dimensions of PA plugs: DN 4/6: L = 111, Ø 50 (F), Ø 75 (A)

DN 6/8: L = 111, Ø 50 (F), Ø 75 (A)

DN 4/6: L = 111, Ø 50 (F), Ø 75 (A)

DN 6/8: L = 120, Ø 54 (F), Ø 79 (A)

Protection class: IP 44 (EN60529)

Electrical

Power supply: 230 VAC 50/60 Hz or 115 VAC 50/60 Hz

Power consumption: 100 W/m

Connection cable: 3 m

Connection plug: 7-pin plug for connecting HT-43 and HT-55 temperature controllers

HANQ8 plug for connection to the HT-41 temperature controller

Points forts

No condensation, no freezing.

Robust external housing.

Excellent insulation.

Optimal heat distribution.

Customised designs.

Easy replacement of the inner core (JH3FR).

Long service life.

Kink.

Fourni avec

Exhaust gas analysis.

Emissions and process monitoring.

Transport of the gas sample from the sampling point to the analysis system.

To remain safely above the acid dew point.

Protection against tampering with measured values and freezing.

Indoor and outdoor use