Hygiène
JCT JH3F & JH3FR : Lignes d'échantillonnage chauffées avec tuyau ondulé
Caractéristiques
Heating controlled up to a maximum of 200°C.
External protection: corrugated polyamide casing.
Thermal insulation provided by a heat-sensitive non-woven fabric.
Ready for use.
Interchangeable inner core for the JH3FR.
Second core for optional calibration gas for example.
Inner core reinforced with stainless steel braiding.
Technical specifications:
Model JH3F / JH3FR
Description: Regulated heated sampling line
External protective sheath: Corrugated polyamide sheath, black
Inner core: Fixed, interchangeable
Field of application: Mobile and fixed installations, indoors and outdoors
Operating data
Operating temperature: max. 200°C.
Operating pressure: max. 10 bar.
Ambient temperature*: From -30°C to +60°C
Construction Material of inner core: PTFE, optionally PFA
Heating element: DIN-compliant design, moisture-proof with protective braiding
Thermal insulation: Thermo-polar
Extremities configurations: PA hard caps, silicone caps, PG36 or PG42.
Maximum sampling line length*: 50 m
Outer diameter of sampling line: DN 4/6 mm / 42 mm, DN 6/8 mm / 42 mm
Minimum bend radius
JH3F / JH3FR:
DN 4/6 mm: 100 mm / 150 mm
DN 6/8 mm: 150 mm / 200 mm
Dimensions of silicone caps:
DN 4/6 : L = 88, Ø 50 (H), Ø 70 (C)
DN 6/8 : L = 88, Ø 50 (H), Ø 70 (C)
Dimensions of PA plugs: DN 4/6: L = 111, Ø 50 (F), Ø 75 (A)
DN 6/8: L = 111, Ø 50 (F), Ø 75 (A)
DN 4/6: L = 111, Ø 50 (F), Ø 75 (A)
DN 6/8: L = 120, Ø 54 (F), Ø 79 (A)
Protection class: IP 44 (EN60529)
Electrical
Power supply: 230 VAC 50/60 Hz or 115 VAC 50/60 Hz
Power consumption: 100 W/m
Connection cable: 3 m
Connection plug: 7-pin plug for connecting HT-43 and HT-55 temperature controllers
HANQ8 plug for connection to the HT-41 temperature controller
Points forts
No condensation, no freezing.
Robust external housing.
Excellent insulation.
Optimal heat distribution.
Customised designs.
Easy replacement of the inner core (JH3FR).
Long service life.
Kink.
Fourni avec
Exhaust gas analysis.
Emissions and process monitoring.
Transport of the gas sample from the sampling point to the analysis system.
To remain safely above the acid dew point.
Protection against tampering with measured values and freezing.
Indoor and outdoor use