Analyseur de mesure fixe

JCT JCL-301 : Système compact de conditionnement des gaz

Veuillez entrer votre adresse email pour télécharger la fiche

×

Caractéristiques

Customisable configuration thanks to a range of extension options.

Base unit with high-performance compressor-based sample gas cooler.

1 or 2 independent channels for sample gases.

Integrated condensate pumps.

Speed-controlled fan.

Connections for an external sample gas pump.

11 status LEDs with event log.

2 status contacts.

Additional options:

Robust and easy-to-maintain fine dust filter

Corrosion-resistant flow meter with

Precision needle valve

Reliable condensate monitoring

Acid dosing pump

RS485 interface

Model JCL-301

Description: Compact gas conditioning system

Cooling principle: Compressor cooling with hot bypass technology

Number of gas channels: 1 to 2

Operation

Water flow rate: max. 120 l/h

Inlet gas temperature: max. +140°C

Inlet dew point: max. +80°C

Outlet dew point: +3°C

Dew point stability (under constant inlet conditions): ±0.1K

Ambient temperature: +5° to +45°C

Operating pressure: 0.2 to 2.2 bar

Ready for operation: < 10 min

Pressure drop at max. flow rate: 2 mbar

Construction

Overall dimensions (W x H x D): 320 x 310 x 328 mm

Installation: Freestanding or wall-mounted

Operating position: Horizontal

Weight: Approx. 22 kg

Housing, colour: 1.5 mm sheet steel, powder-coated, RAL 1016 S

Heat exchanger material: PVDF

Dead volume per gas path: 48 ml

Measurement gas connection / condensate outlet:

PVDF pipe connection DN 4/6 mm

Approvals / marks: CE

Electrical

Power supply: 220 to 240 VAC 50/60 Hz or 100 to 115 VAC 50/60 Hz

Power consumption (depending on load, ambient temperature and configuration):

200 to 345 VA

Power/status signal connection: 3 x EN175301-803 connector, form A/B with PG 9 cable gland, 3/4-pole

Fuses: External at the installation site, fuse rating C

230 VAC 6 A; 115 VAC 10 A

Protection class: IP 20 (EN 60529)

Duty cycle: 100%

Alarm setpoints: < 0 / > +10°C

Status relay: 1 V dry contact (changeover)

Pump relay: 1 V dry contact (normally open)

Relay breaking capacity: max. 250 VAC / 8 A (1.5 A at 250 VDC); min. 5 VADC 5 mA

Data interface (optional): DB 9 female

Interface protocol (optional): RS 485 / ST Bus

Max. bus cable length: 1000 m

Points forts

A comprehensive solution for a wide range of applications.

Reliable and reproducible measurement results over the long term.

Optimal operational safety thanks to self-monitoring.

Extremely accurate and long-term stable dew point, even under varying loads.

Fast response time thanks to low dead volume.

Very low dissolution rates.

Continuous condensate removal.

Low-maintenance operation.

Easy-to-maintain design.

Fourni avec

Exhaust gas analysis.

Emissions and process monitoring.

Continuous conditioning of wet gas samples.

Continuous drying of the gas sample to a precise, low and constant outlet dew point.

Minimises cross-sensitivities to water vapour and volumetric errors.