Analyseur de mesure fixe
JCT JCL-301 : Système compact de conditionnement des gaz
Caractéristiques
Customisable configuration thanks to a range of extension options.
Base unit with high-performance compressor-based sample gas cooler.
1 or 2 independent channels for sample gases.
Integrated condensate pumps.
Speed-controlled fan.
Connections for an external sample gas pump.
11 status LEDs with event log.
2 status contacts.
Additional options:
Robust and easy-to-maintain fine dust filter
Corrosion-resistant flow meter with
Precision needle valve
Reliable condensate monitoring
Acid dosing pump
RS485 interface
Model JCL-301
Description: Compact gas conditioning system
Cooling principle: Compressor cooling with hot bypass technology
Number of gas channels: 1 to 2
Operation
Water flow rate: max. 120 l/h
Inlet gas temperature: max. +140°C
Inlet dew point: max. +80°C
Outlet dew point: +3°C
Dew point stability (under constant inlet conditions): ±0.1K
Ambient temperature: +5° to +45°C
Operating pressure: 0.2 to 2.2 bar
Ready for operation: < 10 min
Pressure drop at max. flow rate: 2 mbar
Construction
Overall dimensions (W x H x D): 320 x 310 x 328 mm
Installation: Freestanding or wall-mounted
Operating position: Horizontal
Weight: Approx. 22 kg
Housing, colour: 1.5 mm sheet steel, powder-coated, RAL 1016 S
Heat exchanger material: PVDF
Dead volume per gas path: 48 ml
Measurement gas connection / condensate outlet:
PVDF pipe connection DN 4/6 mm
Approvals / marks: CE
Electrical
Power supply: 220 to 240 VAC 50/60 Hz or 100 to 115 VAC 50/60 Hz
Power consumption (depending on load, ambient temperature and configuration):
200 to 345 VA
Power/status signal connection: 3 x EN175301-803 connector, form A/B with PG 9 cable gland, 3/4-pole
Fuses: External at the installation site, fuse rating C
230 VAC 6 A; 115 VAC 10 A
Protection class: IP 20 (EN 60529)
Duty cycle: 100%
Alarm setpoints: < 0 / > +10°C
Status relay: 1 V dry contact (changeover)
Pump relay: 1 V dry contact (normally open)
Relay breaking capacity: max. 250 VAC / 8 A (1.5 A at 250 VDC); min. 5 VADC 5 mA
Data interface (optional): DB 9 female
Interface protocol (optional): RS 485 / ST Bus
Max. bus cable length: 1000 m
Points forts
A comprehensive solution for a wide range of applications.
Reliable and reproducible measurement results over the long term.
Optimal operational safety thanks to self-monitoring.
Extremely accurate and long-term stable dew point, even under varying loads.
Fast response time thanks to low dead volume.
Very low dissolution rates.
Continuous condensate removal.
Low-maintenance operation.
Easy-to-maintain design.
Fourni avec
Exhaust gas analysis.
Emissions and process monitoring.
Continuous conditioning of wet gas samples.
Continuous drying of the gas sample to a precise, low and constant outlet dew point.
Minimises cross-sensitivities to water vapour and volumetric errors.