Caractéristiques

SmartFID is suitable for measuring:

Emissions from thermal, catalytic, biological and activated carbon purification systems.

Air purification systems.

Maximum concentration levels in the workplace.

Hydrocarbon emissions in raw gas and clean gas.

Process monitoring and control in manufacturing plants.

Emissions from (combustion) engines.

Detection of hydrocarbons in exhaust air purifiers and chemical cleaning systems.

Emissions from power stations, domestic waste incineration plants and mechanical waste treatment facilities.


Features:
Measured components: Hydrocarbons, chlorinated hydrocarbons
Measuring principle: Flame ionisation detection (FID)
Measuring ranges (relative to C3H8): 5 selectable ranges / automatic range switching:
• Standard: 0 ... 10 ppm to 0 ... 10 Vol.%
• Measurement ranges of the optional probe: 0 ... 1 ppm to 0 ... 1 Vol.%,
Additional measurement ranges freely configurable.
Detection limit: ≤1.5% of the upper range value
Linearity: ±1.0% of the selected range
Repeatability: ≤1.0% at constant temperature and pressure
Zero drift: ≤0.5% of the upper range value per month
Sensitivity: drift ≤2.8% of the upper range value per week
02 cross-sensitivity: < 1.8% relative to 80 ppm C3H8
Warm-up time: 25 min
Typical T90 time: <1.5 s
Measurement gas conditions
Atmospheric pressure: ±0.05 bar
Temperature: 0 - 230 °C
Flow rate approx.: 1.2 l/min
Measurement gas connection: Screw-on clamp for stainless steel tubing, outer diameter 6 mm, or quick-connect fitting

Carrier gas
Combustible gas: Hydrogen, category 5.0, residual hydrocarbon content <0.5 ppm, pressure: 3 bar, consumption in continuous operation: 1.2 l/h; alternatively H2/He mixture, consumption: approx. 2.4 l/h
Calibration gas: Concentration of approx. 80% of the range (typ. propane) in synthetic air, pressure: 3 bar, consumption during calibration process: 1.6 l/min
Combustion air/zero gas: External supply (hydrocarbon-free), pressure: 3 bar
Connector: Quick-connect coupling
Power supply: 115 or 230 V AC 48 ... 63 Hz; power consumption: maximum 350 W for the heating process, typ.
120 W during operation.
Weight: Analyser: 12 kg
Dimensions (H x W x D): 177 mm (4 RU) x 445 mm (19'') x 365 mm
Signal outputs
Analogue outputs: 2 outputs 0...4 - 20 mA, freely configurable
Digital outputs: 3 freely configurable potential-free contacts, 250 V AC 1 A
Compliance: CE, EMC, VDE 0701, DIN EN 15267-3 (planned)

Points forts

● We offer a wide range of additional components for the SmartFID to ensure the device is optimally adapted to your needs.
● Sampling:
● Gas measurement probes
● Filtration systems
● Heated hoses
● Additional modules:
● Methane converter
● Oxygen detection
● Service:
● Consultancy
● Project planning
● Maintenance
● Gas supply:
● Catalytic converters
● Air conditioning
● Petrol stations
● Housing:
● Bench-top
● Wall-mounted
● SmartFID ST hydrocarbon analyser
● Automatic operation with extensive monitoring and safety functions
● Internal data logging
● Network-compatible
● Approved sensor geometry
● Low fuel gas consumption
● Low operating costs
● Internal temperature control for heated lines

Fourni avec

Microprocessor-controlled for automated operation:

5.7" LCD touchscreen for operation and display of operating status.

Measuring range: 0–100,000 ppm / 0–160,000 mgC, configurable automatic switching of the measuring range

Automatic monitoring of essential tasks and parameters

Internal storage of measured values (data logging function), output to a USB device in XML format for direct import into Microsoft Excel

2 configurable measurement value outputs 0/4...20 mA

Integrated heating control for a heated line with a maximum length of 5 metres

Ethernet interface for connecting external modules

Available in different languages