Analyseur de mesure fixe
ERSATEC Smart FID mobile
Caractéristiques
-
● SmartFID is suitable for measuring:
● Emissions from thermal, catalytic, biological and activated carbon air purification systems.
● Maximum concentration levels in the workplace.
● Hydrocarbon emissions in raw gas and clean gas.
● Process monitoring and control in manufacturing plants.
● Emissions from (combustion) engines.
● Detection of hydrocarbons in exhaust air scrubbers and dry-cleaning plants.
● Emissions from power stations, domestic waste incineration plants and waste treatment facilities.
● Government agencies and regulatory bodies.
● Approved sensor geometry.
● Low fuel gas consumption.
● Low operating costs.
● Internal temperature control for heated lines.
● Specifications: Measured components: Hydrocarbons, chlorinated hydrocarbons
● Measurement principle: Flame ionisation detection (FID)
● Measurement ranges (relative to C3H8): 5 selectable ranges / automatic measurement range switching:
• Standard: 0 ... 10 ppm to 0 ... 10 Vol.%
• Measurement ranges of the optional probe:
● 0 ... 1 ppm to 0 ... 1 Vol.%,
● Additional measurement ranges freely configurable.
● Detection limit: ≤1.5% of the upper range value
● Linearity: ±1.0% of the selected range
● Repeatability: ≤1.0% at constant temperature and pressure
● Zero drift: ≤0.5% of the upper range value per month
● Sensitivity: drift ≤2.8% of the upper range value per week
● 02 cross-sensitivity: < 1.8% relative to 80 ppm C3H8
● Warm-up time: 25 min
● Typical T90 time: <1.5 s
● Test gas conditions
● Atmospheric pressure: ±0.05 bar
● Temperature: 0 - 230 °C
● Flow rate approx.: 1.2 l/min
● Test gas connection: Screw-on clamp for stainless steel tubing, OD 6 mm or quick-connect coupling Carrier gas
● Fuel gas: Hydrogen, grade 5.0, residual hydrocarbon content <0.5 ppm, pressure: 3 bar, consumption in continuous operation: 1.2 l/h; alternatively H2/He mixture, consumption: approx. 2.4 l/h
● Calibration gas: Concentration of approx. 80% of the range (typ. propane) in synthetic air, pressure: 3 bar, consumption during continuous operation: 1.2 l/h in synthetic air, pressure: 3 bar, consumption during the calibration process: 1.6 l/min
● Combustion air/zero gas: External supply (hydrocarbon-free), pressure: 3 bar
● Connector: Quick-connect coupling
● Power supply: 115 or 230 V AC 48 ... 63 Hz; power consumption:
● Maximum 350 W during the heating process, typ. 120 W during operation (without catalytic converter)
● Maximum 540 W during the heating process, typically 150 W during operation (with catalytic converter)
● Weight: Analyser: 16 kg
● Dimensions (H x W x D): 420 mm x 470 mm x 310 mm
● Signal outputs
● Analogue outputs: 2 freely configurable 0...4–20 mA outputs
● Digital outputs: 3 freely configurable potential-free contacts, 250 V AC 1 A
● Compliance: CE, EMC, VDE 0701, DIN EN 15267-3 (planned)
Points forts
● For the SmartFID, we offer a wide range of additional components to ensure the device is optimally tailored to your needs.
● Sampling: Gas sensors, Filtration systems, Heated hoses
● Additional modules: Methane converter, Oxygen sensor
● Services: Consultancy, Project planning, Maintenance
● Advantages: Automatic operation with extensive monitoring and safety functions, Internal data logging, Network-compatible, Compact design, Approved detector geometry
● Mobile Smart FID hydrocarbon analyser
● Low fuel gas consumption
● Low operating costs
● Internal temperature control for heated lines
Fourni avec
Microprocessor-controlled for automated operation:
5.7" LCD touchscreen for operation and display of operating status.
Measuring range: 0–100,000 ppm / 0–160,000 mgC, configurable automatic switching of the measuring range
Automatic monitoring of essential tasks and parameters.
Internal storage of measured values (data logging function), output to a USB device in XML format for direct import into Microsoft Excel.
2 configurable measurement value outputs 0/4...20 mA
Integrated heating control for a heated line up to 5 metres in length
Ethernet interface for connecting external modules
Available in different languages
Case with handle and built-in cylinders for hydrogen and test gas