Accessoires de mesure

BUHLER Pompes de gaz de mesure P1.1, P1.1E, P1.2, P1.2E

Veuillez entrer votre adresse email pour télécharger la fiche

×

Caractéristiques

● Technical specifications P1.1/P1.1E

● Rated voltage/Current consumption: 230 V 50 Hz, 0.48 A, 115 V 60 Hz, 0.84 A, 12 V DC, 1.55 A, 24 V DC, 0.8 A

● Protection rating OEM/Housing & 12 V/24 V: IP 00/IP 20

● Mechanical stress: Tested in accordance with DNV-GL CG0339 vibration class A (0.7 g), 2 Hz–13.2 Hz amplitude ± 1.0 mm, 13.2 Hz–100 Hz acceleration 0.7 g

● Weight (without accessories): approx. 1.3 kg (12 V/24 V approx. 0.8 kg)

● Fluid temperature: 70 °C

● Ambient temperature: 0 °C to 50 °C

● Nominal flow rate: 280 l/h

● Materials in contact with fluids depending on configuration: PTFE, PVDF, 1.4571, 1.4401, Viton

● Technical specifications P1.2/P1.2E

● Rated voltage/Current consumption: 230 V 50 Hz, 0.48 A, 115 V 60 Hz, 0.84 A

● Protection class OEM/Housing: IP 00/IP 20

● Weight (without accessories): approx. 1.3 kg

● Fluid temperature: See temperature classes

● Ambient temperature: 0 °C to 50 °C

● Nominal flow rate: 280 l/h

● Materials in contact with fluids depending on configuration: PTFE, PVDF, 1.4571, 1.4401, Viton

● No flammable gases in the gas path at 70 °C

● Flammable gases in the gas path above the LEL

● T3: 70 °C

● T4: 50 °C

Points forts

● Easy-to-replace valves

● Single-piece bellows seal

● Conveys measurement gas containing condensate

● Proven pumping technology

● Attractive price

● Compact design

● IP20 enclosure version

● Optional with integrated bypass valve

● Optional FM C-US (general purpose) approval

● Used in DNV-GL and LR-approved preparation units

● Suitable for use in systems compliant with IMO MARPOL MEPC.259(68)

● Special design for use in high-vibration environments

Fourni avec