Etalonair | Calibration under ISO 17025
calibration FID NO CO CO2
Société d'étalonnage de JUM, de HORIBA, analyseur de gaz et capteur CO2
Chemistry and reference materials
Calibration under COFRAC accreditation of gas analyzer and sensor (CO/CH4/NO/ CO2/02)
Gas Analyzers Accreditation
N. 2-5904 Scope available at
www.cofrac.fr

Giving meaning to measurement

Since 2015, our laboratory has been accredited to generate reference gas concentrations measured on continuous signal gas analysers.

Internal and standardized methods are used to obtain calibration results.

Our calibration benches, designed by ETALONAIR, allow us to achieve a wide range of reference concentrations, in single dilution (binary mixture) or in double dilution (ternary mixture).

We are accredited on the following compounds, either principal or interfering: O₂, CO, CO₂, NO, NO₂, SO₂, C₃H₈, and CH₄.

Many other compounds are available outside of accreditation: N₂O, NH₃, He, C₂H₆, etc.

The laboratory shall issue either a verification statement (conformity assessment against customer specified requirements) or a calibration certificate.

Our methods :


Result Mesurand unit Method
Lack to fit
(A)
mol.mol-¹ EN 15267-3 (2008) §10.12 and appendix C
EN 15267-4 (2017) §10.9 and appendix C
EN 12619 (2013) appendix A.3
ISO 25140 (2010) appendix B.5
MET-1
Repeatability
(A)
mol.mol-¹ EN 15267-3 (2008) §10.10, §10.11
EN 15267-4 (2017) §10.7, §10.8
EN 12619 (2013) appendix A.4 and A.5
ISO 25140 (2010) annexes B.3 et B.4
Limits mol.mol-¹ EN 15267-3 (2008) §6.10
EN 15267-4 (2017) §6.4
Response time s EN 15267-3 (2008) §10.9
EN 15267-4 (2017) §10.6
EN 12619 (2013) appendix A.2
ISO 25140 (2010) appendix B.2
Response factor to an organic compound dimensionless EN 15267-3 (2008) §10.22
EN 15267-4 (2017) §10.18
EN 12619 (2013) appendix A.8
MET-1, MET-2
NMHC rejection efficiency % ISO 25140 (2010) appendix B.7
MET-1, MET-2
Oxygen influence
(A)
% PE EN 15267-3 (2008) §10.19
EN 15267-4 (2017) §10.16
EN 12619 (2013) appendix A.6
ISO 25140 (2010) appendix B.6.3
MET-1, MET-2
Cross sensitivity to interferents
(A)
% PE EN 15267-3 (2008) §10.19 and appendix B
EN 15267-4 (2017) §10.16 et appendix B
EN 12619 (2013) appendix B.2.5
ISO 25140 (2010) appendix B.6.2
MET-1, MET-2
Conversion efficiency NOx/NO
(A)
% EN 14792 (2017) appendix C.2
MET-1, MET-2
(A) under accreditation

This link gives you the normative criteria according to the standards


Our complete scope of accreditation is available here.

These activities include, but are not restricted to :
 calibration O2, CO, CO2, NO, NO2, SO2, C3H8, et CH4
- Lack to fit ;
- Repeatability at zero and span ;
- Response time ;
- Cross sensitivity to interferents ;
- Oxydation catalyst efficiency measured with éthane ;
- Linearity, regression line ;
- Detection and quantification limits ;
- Response factor to an organic compound ;
- Oxygen influence ;
- Gas converter efficiency.


COMMITMENT - KNOWLEDGE


Our experience and our own research in metrology make it possible to perform the calibration of your analyzer with increased time savings and deliver the report as soon as the instrument returns.

Our processing capacity makes it possible to absorb a large number of requests throughout the year.

Our know-how in the development of reference concentrations, binary or ternary, allows us to respond to all requests.

Our planification skills allows to shortern delivery time even more.

Our mastering of calibration combined with automation make us extremely responsive and impartial on the results, with a quick delivery of the report.

Our quality manual, sent on request, presents all our policies, commitments and provisions to meet all the requirements of ISO 17025.


EFFECTIVENESS


The synergy between our teams ensure continuity of service and saves time to resolve non-conformities.

Outsourcing repair, maintenance and calibration under a same banner allows you to reduce costs, dowtime and transport damages.



DO NOT HESITATE TO SUBMIT ALL YOUR REQUESTS !

Call us at :

numéro de téléphone +33 967 124 329 or +33 442 104 329

adresse contact contact@etalonair.com

Etalonnage COFRAC AHLBORN FY A600-CO2 Etalonnage COFRAC ALMEMO FYA600-CO2 Etalonnage COFRAC ANALYSEUR BIOGAZ ASCO Etalonnage COFRAC ANALYSEUR COMBUSTION KIMO TESTO ECOM Etalonnage COFRAC AP2E PROCEAS Etalonnage COFRAC API0200PLUS O2M42 Etalonnage COFRAC BERNATH ATOMIC 3600 Etalonnage COFRAC BERNATH ATOMIC 9900 Etalonnage COFRAC BUEHLER BA3 SELECT Etalonnage COFRAC CHAUVIN ARNOULT CA 1510 Etalonnage COFRAC COSMA Graphite 355 Etalonnage COFRAC COSMA Graphite 655 Etalonnage COFRAC COSMA BERYL 102 Etalonnage COFRAC COSMA Graphite 55 Etalonnage COFRAC COSMA Graphite 730 Etalonnage COFRAC COSMA Graphite 655 Etalonnage COFRAC COSMA Graphite 730 Etalonnage COFRAC COSMA BERYL 102 Etalonnage COFRAC COSMA G730 Etalonnage COFRAC ECOM JK2N Etalonnage COFRAC ECOPHYSICS CLD 62 Etalonnage COFRAC ECOPHYSICS CLD 82S Etalonnage COFRAC ECOPHYSICS CLD 82S Etalonnage COFRAC ECOPHYSICS 882 MHR Etalonnage COFRAC ECOPHYSICS CLD 82S Etalonnage COFRAC EMERSON XSTREAM Etalonnage COFRAC ENVIRONNEMENT SA Graphite 52M Etalonnage COFRAC GAS DATA PCO2 Etalonnage COFRAC GEOTECH G100 Etalonnage COFRAC GEOTECH Etalonnage COFRAC HORIBA PG 250 Etalonnage COFRAC HORIBA PG 350 Etalonnage COFRAC HORIBA PG 350 Etalonnage COFRAC HORIBA VA 3011 Etalonnage COFRAC HORIBA MEXA Etalonnage COFRAC HORIBA APHA 370 Etalonnage COFRAC INDUSTRIAL SCIENTIFIC OXYGENOMETRE PRO GAS BADGE Etalonnage COFRAC INFICON XL3000 FLEX Etalonnage COFRAC JRI SONDE CO2 Etalonnage COFRAC JUM ENGINEERING 3-200 Etalonnage COFRAC JUM ENGINEERING 3-600 Etalonnage COFRAC JUM ENGINEERING 3-800 Etalonnage COFRAC JUM ENGINEERING 109A Etalonnage COFRAC JUM ENGINEERING 109L Etalonnage COFRAC JUM ENGINEERING 109A-OVE Etalonnage COFRAC JUM ENGINEERING 3-900 Etalonnage COFRAC JUM ENGINEERING 3-800 Etalonnage COFRAC KIMO CO DIAG+ Etalonnage COFRAC KIMO CO50 Etalonnage COFRAC KIMO AQ110 Etalonnage COFRAC KIMO KCC320 Etalonnage COFRAC M&C PMA 10 Etalonnage COFRAC MBE ELECTRONIC AG HELOX 2 Etalonnage COFRAC MC2 SONDE CO2 Etalonnage COFRAC OCEASOFT SONDE CO2 Etalonnage COFRAC Oldham EX 2000 Etalonnage COFRAC POLARIS FID SE Etalonnage COFRAC PYRESCOM CLASS AIR Etalonnage COFRAC QAI QAI Etalonnage COFRAC RATFISCH RS 53-T Etalonnage COFRAC SEITRON CASPER 301s Etalonnage COFRAC SERVOMEX 1440C Etalonnage COFRAC SERVOMEX 4100 Etalonnage COFRAC SERVOMEX Multigaz 4904C Etalonnage COFRAC SERVOMEX 1440 Etalonnage COFRAC SERVOMEX 1100A Etalonnage COFRAC SERVOMEX Xentra 4900 Etalonnage COFRAC SERVOMEX 4101 MULTI EXACT Etalonnage COFRAC SERVOMEX SERVOFLEX MICRO I.S Etalonnage COFRAC SERVOMEX 4100 MULTI EXACT Etalonnage COFRAC SERVOMEX XENTRA 4100 Etalonnage COFRAC SERVOMEX MULTIEXACT 4100 Etalonnage COFRAC SERVOMEX 4100 Etalonnage COFRAC SERVOMEX Gas O2 purity Etalonnage COFRAC SERVOMEX 4904C Etalonnage COFRAC SERVOMEX 1440C Etalonnage COFRAC SETNAG OXYMETRE Etalonnage COFRAC SIEMENS Oxymat 6E Etalonnage COFRAC SIEMENS Ultramat 23 Etalonnage COFRAC SIEMENS Ultramat 22P Etalonnage COFRAC SIEMENS Oxymat 6E Etalonnage COFRAC TESTO 330 -1LL Etalonnage COFRAC TESTO T320 Etalonnage COFRAC TESTO 317-3 Etalonnage COFRAC TESTO 317-5 Etalonnage COFRAC TESTO 311-1LL Etalonnage COFRAC TESTO 320 Etalonnage COFRAC TESTO 330 -1LL Etalonnage COFRAC TESTO T320 Etalonnage COFRAC TH INDUSTRIE DK660 Etalonnage COFRAC THERMO TEI 42i Etalonnage COFRAC THERMO 42 I-HL Etalonnage COFRAC THERMO 42CHL Etalonnage COFRAC TITRATION NO2 20ppm Etalonnage COFRAC TRS AF21M Etalonnage COFRAC TRS AF22M Etalonnage COFRAC UTRAMAT 22P Etalonnage COFRAC OCEASOFT CUBIC Etalonnage COFRAC VAISALA SONDE CO2 GMP 221 Etalonnage COFRAC VAISALA CO2 PROBE GMP251 A2B0C1N2 Etalonnage COFRAC VIGAZ BOX120-USB Etalonnage COFRAC WITT OXYBABY